LYC-B-series ZLYC series LY series LYC-J series LYC-C series LYC-A series BLYJ series GLYC sreies LYC-G series PALL PFU oil purifier device PALL HNP oil purifier PALL HVP vacuum oil purifier PALL HCP oil purifier PALL HEP oil purifier PALL PFC oil filtration cart PALL PFS oil purifier device LUCA Filter Pushcart LUC Filter Pushcart LUCB Filter Pushcart
Position:Home > Product > Filter > Pressure Line Filter >
XNL TANK MOUNTED RETURN LINE FILTER SERIES
1.INTRODUTION
The XNL-series return line filter ia s new type filter. It is used in the return line of hydraulic system to
remove all the contaminants and keep the oil cleaning when the oil return to the tank. This series
filter has some features as follow:
a) it can be installed on the top of the tank
b) the contanminants inside the element can be taken out when cleaning the element
c) there is a by-pass vavle on the top of the element, when the pressure drop across the filter element attains
0.4Mpa, the vavle will open to protect the hydraulic system safty
d) the parmanent magnets inside the filter can filterthe magneyic particles above 1 um dia from the
oil.
If you close the XNLseries filter, the indicator should be quiped. When the pressure drop across
the element reaches 0.35Mpa, the element must be changed
MODEL |
Flow Rate (L/MIN) |
FILTR (UM) |
Dia (mm) |
Press (Mpa) |
Initial Δp
|
Indicator |
By-pass setting (Mpa) |
Weight |
Model of element |
||
Initial |
Max |
V |
A |
||||||||
XNL-25X*-C/Y |
25 |
1 3 5 10 20 30
|
20 |
0.6 |
≤0.1 |
0.35 |
12
24
36
220 |
25
2
1.5
0.25 |
0.4 |
1.2 |
NLX-25X* |
XNL-40X*-C/Y |
40 |
1.5 |
NLX-40X* |
||||||||
XNL-63X*-C/Y |
63 |
32 |
2.3 |
NLX-63X* |
|||||||
XNL-100X*-C/Y |
100 |
2.5 |
NLX-100X* |
||||||||
XNL-160X*-C/Y |
160 |
50 |
4.6 |
NLX-160X* |
|||||||
XNL-250X*-C/Y |
250 |
5.1 |
NLX-250X* |
||||||||
XNL-400X*-C/Y |
400 |
80 |
10.1 |
NLX-400X* |
|||||||
XNL-630X*-C/Y |
630 |
10.8 |
NLX-630X* |
||||||||
XNL-800X*-C/Y |
800 |
90 |
14.2 |
NLX-800X* |
|||||||
XNL-1000X*-C/Y |
1000 |
14.9 |
NLX-1000X* |
NOTE:* IS filtration accuracy,if the medium is water-glycol,flow rate is 160L/min,filtration accuracy is 10 um,with CYB-I Indicator,the model of this filter is XNL.BH-60X10Y,The model of element is NLX.BH-160X10.