RFLD Double Line filter

RFLD Double Line filter


 



1.MODEL COLD

RFLD  BN/HC  1300  C   A   K   10   D    1    X   

 (1)      (2)    (3)    (4)  (5)  (6)  (7)   (8)  (9)   (10)

Detailed Explanation :

             (1)RFLDThe form of filter

   (2)BN/HC : Material of filter element    

 BN/HC ,W/HC

(3)1300: Specification

  1300/1320/2500/2520/4000/4020/5200/5220/6500/6520/7800/7820/5000/5020

(4)C:Working pressure       C=16bar

(5)A : Switching valve forms     

(6)K : Connection Type / Specifications

(7)10Filtration precision (μm)    

  BN/HC ,BH/HC : 3,5,10,20

  P/HC : 10,20

  W/HC : 25,50,100,200

(8)D :Form of pollution sender device 

A : Mounting holes closed indented bolts

B: With visual pollution sender

C: With electrical pollution sender

D: Visual / electrical pollution sender

(9)1: standard connector

  (10)X : Latest version

2.Parameter

   Flow : 15000L/min

Material : Welded carbon steel / stainless steel

Pressure : 16bar

3.Matching the filter description

Specification : 0950/1300/1700/2600

Form :  R  

   Filtration precision (μm) :   

      BN/HC : 3,5,10,20

      W/HC: 25,50,100,200

Filter material : BN/HC ,P/HC,W/HC