Oil Purification products
Air Compressor Filter
Air Compressor Inline Filter
Water purification equipment
Air Purification Products
Brand Name:
Model Number:
Nominal filtration rating:
Application:
Operating pressure:
Working temperature:
Replacement or not:Replacement
The Reverse Osmosis Membrane Model AG4040F is a high - performance water treatment component. It uses advanced reverse osmosis technology to actively separate dissolved salts, heavy metals, bacteria, viruses, and other minute contaminants from water. Engineered with precision, this membrane targets the most demanding water purification needs in multiple industries and applications. By applying pressure to force water through its semi - permeable structure, it effectively filters out impurities, producing high - quality, purified water.
Exceptional Salt Rejection: Actively rejects a large percentage of dissolved salts, ensuring a low - salinity output. This high salt rejection rate is crucial for applications where water with extremely low salt content is required, such as in the electronics and pharmaceutical industries.
Micro - Filtration Precision: Can remove contaminants down to the nanometer scale. It captures even the tiniest particles, providing ultra - pure water suitable for high - precision manufacturing processes and medical applications.
Durable and Long - Lasting Material: Made of robust materials that resist chemical corrosion and mechanical stress. This durability ensures long - term, stable performance, reducing the frequency of membrane replacements and associated maintenance costs.
Efficient Water Permeation: Allows for a high flow of purified water while maintaining excellent filtration efficiency. This means it can handle large volumes of water, meeting the demands of both small - scale and large - scale water treatment applications.
Temperature: Operates best within the range of 5 - 45 °C. Temperatures outside this range can impact the membrane's performance, with lower temperatures reducing water permeability and higher temperatures potentially damaging the membrane material.
Maximum Operating Pressure: Can withstand up to 4.1 MPa. Applying pressure beyond this limit may cause the membrane to rupture or lose its filtration effectiveness.
Feed Water Turbidity: The turbidity of the feed water should be ≤ 1 NTU. High turbidity can lead to membrane fouling, reducing its lifespan and filtration efficiency.
Feed Water SDI (Silt Density Index): An SDI value of ≤ 5 is recommended. Higher SDI indicates a higher concentration of suspended solids in the feed water, which can also foul the membrane and impede its performance.
pH Range: Functions effectively in a pH range of 2 - 11. Extreme pH values can chemically attack the membrane, degrading its performance over time.
Brackish Water Desalination: Actively treats brackish water sources, removing salts and impurities to produce potable water. This is especially valuable in areas with limited freshwater resources, such as arid regions or coastal areas with access to brackish groundwater.
Industrial Water Treatment: Used in industries like electronics manufacturing, where ultra - pure water is essential for producing high - precision components. In the pharmaceutical industry, it ensures the purity of water used in drug formulation and production, meeting strict quality control standards.
Municipal Water Treatment: Incorporated into municipal water treatment plants to enhance the quality of source water, whether it's surface water or well water. It helps meet the strict standards for public water supply, improving the overall drinking water quality for the community.
Water Reuse and Recycling: Treats secondary or tertiary treated wastewater, removing remaining dissolved solids, organic matter, and salts. The treated water can then be reused for non - potable applications like irrigation, industrial cooling, and toilet flushing, promoting water conservation.
Membrane Area: 40 square feet (approx. 3.72 square meters), providing a sufficient surface area for efficient water treatment. Larger membrane areas generally allow for higher water treatment volumes.
Nominal Salt Rejection Rate: 99.5% (typical value, may vary slightly depending on operating conditions). This high salt rejection rate ensures effective removal of dissolved salts from the water.
Permeate Flow Rate: 750 - 950 gallons per day (approx. 2.8 - 3.6 cubic meters per day), depending on factors such as feed water quality, temperature, and pressure. Higher flow rates are achievable under optimal conditions.
Membrane Type: Thin - Film Composite (TFC) membrane. TFC membranes are known for their high performance in rejecting contaminants and providing long - term durability, making them suitable for a wide range of water treatment applications.
In conclusion, the Reverse Osmosis Membrane Model AG4040F is a top - tier water treatment solution. Its advanced features, including high salt rejection, micro - filtration precision, and durable construction, make it a reliable choice for various industries and applications. The well - defined operating conditions and clear technical data ensure consistent and efficient performance. Whether it's providing clean drinking water, supporting high - precision industrial processes, or contributing to water conservation through reuse, this membrane plays a crucial role. As the demand for high - quality water treatment solutions continues to grow, the AG4040F is well - positioned to meet these challenges, offering a cost - effective and efficient way to purify water and improve water quality.
Dow | Hydranautics | Toray | CSM | GE | VONTRON |
---|---|---|---|---|---|
BW30XFR-400/34 | ESPA1-4040 | TMH20A-400C | RE4040-BLR | AG8040F-400FR,34 | SW4040HR |
BW30FR-400/34 | CPA2-4040 | TMH20A-440C | RE8040-BE | AG8040F-400 | ULP21-8040 |
BW30-400/34 | PA3-LD | TMG20-370C | RE8040-BLN | AG8040F-400LF | ULP2012 |
BW30-400/34i | SWC5-LD | TMG20-400C | RE8040-BLR | AG4040FM | ULP1812 |
BW30-400 | ESPA2-4040 | TMG20-440C | RE4040-BE | AG8040F-365 | ULP32-8040 |
BW30-400IG | YQS-4040 | TMG20D-400 | RE4040-BLN | AG8040N-400 | ULP31-4040 |
BW30-365 | ESPA2-7 | TMG20D-440 | L-RO-4040 | AK4040FM | ULP22-8040 |
BW30XFR-400/34i | CPA6-LD | TM720-370 | RE1812-HR50 | AG4040F | ULP21-4040 |
BW30FR-400/34i | ESPA2 MAX | TM720-400 | RE1812-HR75 | ULP2012 | |
BW30HRLE-440 | LFC3-LD | TM720-440 | RE4040-TE | ||
BW30HRLE-440i | ESPA2 | TM720C-440 | RE2521-TE | ||
XFRLE-400/34i | PR0C10 | TM720D-370 | RE2540-TE | ||
SW30HRLE-400 | PR0C20 | TM720D-400 | RE4040-TE | ||
BW30FR-400/34i | ESPA2-4040 | TM720D-440 | RE4040-TL | ||
BW30XFRLE-400/34i | ESPA4-4040 | TML20N-400 | ETC. | ||
BW30LCHR-4040 | CPA3-LD-8040 | TML20DA400 | |||
BW30-4040 | SWC5-8040 | TML20D-370 | |||
LCLE-4040 | YQS-8040 | TML20D-400 | |||
BW30HRLE-4040 | ESPA2-8040 | TMH10A | |||
SW30-4040 | ESNA1-LF-LD | TMG10D | |||
BW30HR-380 | ESNA1-K1 | TM710D | |||