DATE:2023-08-02Number of views: Source:LEFILTER
With the increasing demand for industrial water use, large-flow filter filters are becoming more and more important. In order to replace the filter element in time and maintain the efficiency of water purification, it is necessary to set the early warning upper limit of the filter element correctly. This article will introduce what early warning ceiling should be set by the large flow filter element.
1. Assemble the data acquisition sensor
Nowadays, most of the intelligent large flow filter elements will be built in a variety of data collection sensors, can monitor the filtration rate, water pressure, water temperature and other operating parameters. Data from these sensors can be monitored for alert.
2. Water consumption is an early warning
Use time is an important indicator that can reflect the state of filter element damage. According to the filter element type, the early warning upper limit of water consumption can be set.
For example:
1. Standard type: usually the limit is generally 10,000 gallons, as the latest replacement time.
2. High efficiency type: it can be limited to 20,000 to 40,000 gallons, and the service life of the efficient filter element is longer.
3. Water pressure warning
When the filter element blocks, the water pressure will increase significantly. The upper water pressure can be set according to the filter type:
1. Standard filter element: if the water pressure exceeds 60 to 80 PSI, the upper limit is triggered.
2. High efficiency filter element: if the water pressure exceeds 80 to 100 PSI, the upper limit is triggered.
4. Leakage warning
When the filter element leaks, it should be replaced immediately. The upper limit of leakage can be set by monitoring the difference between raw water and filtered water.
5. The odor warning
When the filter water smells, it indicates that the filter element has been damaged and needs to be replaced. It is recommended to set the upper limit of the manual input trigger.
The above warning limits should be set according to the actual filter type and usage scenarios.
Monitoring and early warning can find the problem of the filter element in time, and remind users to replace the filter element in time, to ensure the efficiency of water purification and the stability of the system.